UNIT TRANSMISSION VALVE CBSA-1
Purpose of the development:
Signaling device valve CBSA-1 is designed to transmit and receive signals of alarm systems pulsed solenoid valve to ensure it is closed when triggered alarm systems of gas pollution, fire and security alarms, power outages, and the inclusion of light and sound the alarm when it detects gas pollution.
CBSA-1 performs the following functions:
provides delivery (duplicates) of light signals "gas leak", "Fire", "Hacking" on the front panel when the alarm is triggered similar device connected to the alarm systems;
ensures delivery of signals to close the valve;
memory provides the alerts if the main and backup power and play it after the power supply;
when the signal "gas leak" provides the power light and sound signaling (ESS) - a DC voltage of 12 V.
Technical characteristic:
characteristic
Time on internal redundant power supply:
in standby mode, the hour, at least 24
in alarm (with a total power consumption of no more than 20 SES VA), min, at least 40
Power consumption, not more than 10
Overall dimensions, mm, no more than 290 x 220 x 120
Weight, kg, not more than 5.5
MTBF, hours, at least 30,000
Total average service life, years, at least 15
Power sensors are:
basic - AC 220 V
reserve - the built-in DC power supply voltage 12.0 V
The development stage readiness:
Introduced in production
Description of the development:
() CBSA-1 performs the following functions:
- Provides delivery of signals to close the valve;
- Provides memory received signals if the main and backup power and play it after the power supply;
- PR signal comes "gas leak" provides the power light and sound signaling (ESS) - a DC voltage of 12 V.
CBSA-1 is an ordinary performance and intended to be installed outside the hazardous area.
Backup battery power supply is automatic (if the main power supply).
Number of alarms US-1 connected to the CBSA-1 is not more than four. Number of gas detectors, connected in parallel to a gas leak in the connector-50.
By CBSA-1 can be connected to alarm flammable gases and vapors thermochemical SHIELD-2 signaling SHIELD-3, Domestic gas detectors SGB-1, SOS alarm-1 or other types of gas detectors with relay output contacts to the closure, and the fire and alarm with relay output contacts to open or close.
Operating conditions.
Ambient and controllable environment, degree. From 1 to 40
The relative humidity at 25 degrees. C, 80%
Atmospheric pressure, kPa (mm Hg) from 84 to 106.7 (630 to 800)
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|