CARP-EXPLOSION METERS THERMOCHEMICAL CTX-17
Purpose of the development:
Signaling eksplozimetry-CTX-17 are designed to control up to hazardous concentrations of flammable gases and vapors of flammable liquids and set in the air and put out on exceeding the measured concentration.
Recommended application field:
Signaling eksplozimetry-CTX-17 used in the chemical, oil and gas and other industries, utilities, ships and offshore facilities, supervised Maritime Register of Shipping.
CTX-17 used wherever there is a danger of explosion of flammable gases and vapors, such as:
- Wells, pits before the hot work;
- To empty the tank from the fuel;
- In the boiler at ignition on gas boilers;
- In the process of oil production, oil refining, natural gas production;
- On oil and gas pipelines, gas stations;
- A fuel depot in ports and railways, oil depots, aircraft storage facilities;
- In the storage tanks of petroleum products, alcohol, etc.;
- Stations draining oil from tankers arriving to various transport and racks overflow of oil products;
- At the pumping stations and other oil and gas, chemical and other industries, the object under surveillance Maritime Register of Shipping.
Technical characteristic:
Display range CTX-17% LEL 0.00 to 99.9
Measurement range,% LEL: 0 to 55
Maximum permissible
absolute error,% LEL:
- Verification component for ± 5
Range, which can be installed
threshold signal concentration
on request,% LEL of 10 to 45
Nominal values ??of threshold devices,
% LEL:
- For signal "Threshold 1" 20
- For signal "Threshold 2" 40
The sound pressure level on the axis sounder
at a distance of 0.3 m, dB, not less than 60
Warm-up time, with no more than 20
The time of issuing the signal, with no more than 10
Current consumption of the CTX-17 mA, not more than 180
Continuous operating time without recharging
hours, not less than 10
Overall dimensions with integrated SE, mm, not more than 45 x 185 x 35
- Remote sensor, mm, not more than 70 s? 14.5
- The length of the cable remote sensor, 2.0 m
Weight, kg, not more than:
- With built-in 0.3
- With remote sensor 0.35
MTBF, hours, not less than 50,000
Total average service life, years, at least 10
Advantages over analogues:
- Wide range of indications: 00.0 - 99.9% LEL;
- Explosion-proof, explosion-proof marking - "1ExdibsllCT4";
- Diffusion and forced (with attachment), the sample;
- Digital display of the current value of the concentration on the three-digit seven-segment display;
- Self-test in automatic mode;
- Minimal maintenance, ease of operation;
- The presence of two alarm thresholds;
- High metrological characteristics, does not require additional equipment to adjust operating parameters;
- Ability to control the remote sensor;
- Protect access to settings and endpoints of an emergency condition.
The development stage readiness:
Introduced in production
Description of the development:
() Compact alarm eksplozimetry-CTX-17 are individual single-channel portable devices with a continuous audible and visual alarms, with convection or forced (using nozzles) fed a controlled environment.
Alarm CTX-17 successfully combines the latest digital technology with the classic technology gas analysis equipment, smooth and easy to control with compact control.
In alarm mode, the CTX-17 provides delivery of light and sound signaling "Threshold 1" and "Threshold 2".
While eksplozimetra displays on the light indicator of the current value of the concentration of a single component in% LEL and the issue of light and sound signals "Threshold 1" and "Threshold 2".
As an option value of the concentration of single or separate (from the set) controlled components can be represented as a volume fraction (with metrological certification).
Power sensors are built-in rechargeable power supply voltage of 2.1 to 2, 8 V.
Operation:
Ambient and controlled environment of -40 degrees C to +55;
Relative humidity at 25 degrees C, 98%;
Atmospheric davdenie, kPa (mm Hg) from 84 to 106.7 (630 to 800)
Modification of signaling CTX-17
Execution of the CTX-17 are controlled by a component Calibration
CTX-17-80 and a set of components Methane Methane (CH4)
CTX-17-81 Hydrogen and aggregate components of hydrogen (H2)
CTX-17-83 Ethanol (ethyl alcohol), propane (C3H8)
CTX-17-84 Propane Propane (C3H8)
CTX-17-85 n-butane, n-butane (n-C4H10)
CTX-17-86 n-Hexane n-Hexane (n-S6N14)
CTX-17-87 gasoline n-hexane (n-S6N14)
CTX-17-88, isobutane isobutane (i-C4H10)
The design concept provides for built-in power-sensitive elements (SE), and for the remote sensor.
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine