EXCHANGER VPU-2, 5
Purpose of the development:
Designed for heating and humidifying the air blowing through the use of waste gases, gas consuming heat boilers.
Recommended application field:
Areas of use: stationary heating and industrial boilers and heaters with heat output of 2 MW boilers (steam capacity of 2.5 t / h), which consume natural gas.
Technical characteristic:
Specifications:
- Heating, MW 0.16;
- Vitriti combustion products, cubic m / hr. 2500;
- The temperature of the combustion products at the exit, ° C 75;
- The cost of air, cubic meters / hr. 2300;
- Outlet air temperature, ° C 50;
- The cost of water, which is supplied to
air heater, t / h 3;
- The cost of water, which is served outside
consumer, t / h 1.5;
- The temperature of hot water, ° C 70;
- Reduction of oxides, 40-50%;
- Aerodynamic resistance movement
combustion products, Pa. 300;
- Aerodynamic resistance movement
Air Pa. 250;
- The cost of fuel saved, cubic m / hr. 15;
- Overall dimensions 1818x1510x2870;
- Weight, kg 1992.
Advantages over analogues:
Advantages over existing counterparts: lower height due to the use of surface water heater and cross Gumen contact air heater, a large heated circulating water, which provides a higher degree of moisture duttovogo air and a corresponding decrease in emissions of oxides of nitrogen, less aerodynamic drag.
The development stage readiness:
Ready for application
Technical and economic effect:
The use of heat recovery provides increased fuel utilization factor of 6 - 8% reduction in nitrogen oxide emissions by 40-50%. Payback period for the installation of heat recovery without environmental impact - up to 3 years.
Information about newness of the development:
there are Ukrainian patents -- 1 items
corresponds technical description
Ready for implementation
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|