Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

ULTRASONIC LEVEL GAUGE UUS-00


Purpose of the development: Level modifications UUS-00 with patch transducers (probes) are used for level control of liquids in unsealed and sealed with a single-walled tanks and other metallic sound transparency of the walls, with access to the bottom of the tank and not in the absence of sound transparency of the layer of solid precipitation on the bottom.

Recommended application field: Level modifications UUS-00, designed for installation on the tank farms for oil and gas processing plants, storage of oil and gas, as well as corrosive and toxic liquids.

Technical characteristic: Main technical characteristics of the transmitter UUS-00: - The number of serviceable tanks - to 64 inclusive; - Measuring range level of level of this modification from 0.1 to 15 m; - A range of measurements of the interface between two immiscible liquids of different densities - from 0.1 to 14.9 m; - A range of commercial water-level measurements - from 0 to 0.1 m; - A range of measurements of the velocity of sound in liquids - from 200 to 3000 m / s; - Measuring range of temperature - from minus 50 to plus 80 ° C. Maximum permissible absolute error in the measurement of: ± 1 mm - in the range from 0.1 to 15 m inclusive. Maximum permissible absolute error in measuring the velocity of sound in liquids - ± 0,3 m / s. Maximum permissible absolute error in measuring the level of produced water - ± 2 mm. Maximum permissible absolute error in the measurement of temperature - ± 0,5 ° C. Maximum permissible relative error in calculating the amount of calibration tables, introduced in their memory - 0.01%. Power supply - a network of DC 24 V or 15 V (in accordance with the order), galvanically isolated from the AC, the tolerance voltage direct current is not more than - 15%. When using the 24V supply voltage in the transmitter of the device further includes an intrinsically safe power supply device (PIP). Maximum current consumption - no more than 0.3 A. Degree of protection components of level of penetration of water, dust and foreign particles - IP 65. The range of ambient temperature during operation - from minus 40 to plus 50 ° C. Mean time between failures - at least 67,000 hours. Average life - at least 14 years of age.

Advantages over analogues: According to the gauge counterparts in Ukraine. Level of this modification are essential for monitoring reservoirs of liquefied gases and corrosive and toxic liquids, as does not require installation of depressurization and degassing of storage tanks.

The development stage readiness: Introduced in production

Description of the development:
()
Install transducers - the outside of the tank, with no access to the bottom inside the tank can cut a special sealed tube. Height-controlled tanks - up to 15 m thickness of the walls through which the radiation is probing signals and receiving echoes from a liquid / gas-air medium - up to 50 mm.

Possibility of transfer abroad:
Licence's sale
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: