MEASURING SYSTEM "STRUNA"
Purpose of the development:
The system of "String" is designed to measure temperature, density, pressure, mass, calculating the volume of light petroleum products and liquefied gas (LPG) in single-and double-walled tanks, indicate the presence and measure the level of produced water, raising the level of fire and environmental safety, process automation accounting of oil at the gas station, gas stations, oil depots (UXO), food and chemical industries.
Recommended application field:
Tank farms, food processing and chemical industries.
Technical characteristic:
System Specifications:
The range of level measurement (without density) from 120 mm to 4000
The range of level measurement (with a densitometer "surface"), from 200 mm to 4000
The range of level measurement (with a densitometer "dip"), from 150 mm up to 18000
The range of level measurement (for the calibration of tanks), from 0 mm to 4000 or from 0 to 9000
Limits of abs. error in the range up to 4 meters, mm ± 1,0
Limits of abs. error in the range of over 4 meters, ± 2,0 mm
Resolution, ± 0,1 mm
Operating temperature range sensing device parameters (PPP), -40 degrees C to +55
Maximum permissible absolute error of temperature measurement, ± 0,5 degrees C
Measurement ranges of density, kg/m3:
A range (LPG) from 499 to 599
Range 2 (AI-80) from 690 to 760
3 range (A-92, AI-95, A-98) from 715 to 785
4 range (DT) from 810 to 880
Additional limits. abs. measurement error density ("surface."), kg/m3 ± 1,5
Additional limits. abs. measurement error density ("Immersion"), kg/m3 ± 1,0
Alarm Levels pdtovarnoy water level (for petrol), 25 mm
The range of measurements of bottom water (for NB), mm from 80 to 300
Limits dop.absolyutnoy measurement error in water level (for NB), mm ± 1,0
The range of pressure measurements, from 0 MPa to 1.6
The limits of measurement error dop.privedennoy pressure,% ± 1,0
Number of tanks controlled by one (central part) to 16
The cable length from each tank to the operator, no more, m 1200
Parameters of control channels in the control unit (CU):
power circuits (optosemistor) ~ 220V; (from 0.1 to 0,5 A)
power circuits (dry contact) ~ 220V; (from 0.01 to 0,1 A)
low-power relay circuit (dry contact) = 27V, (from 0,01 to 0,5 A)
Power systems 220V +10-15% 50Hz, 0.6 A
The development stage readiness:
Introduced in production
Description of the development:
() The system of "Strings" provides:
"High-precision measurement of distance, density and temperature of liquids, including food and hazardous liquids (gasoline, JP, oils, alcohols, kerosene, LPG, etc.);
"Calculation of volume and mass calibration table of tanks;
"A fully automated accounting movement of petroleum products at gas stations when used in conjunction with the systems of leave;
"Automatic control of single-and double-walled containment (liquid-filled) tank with the inclusion of sound and light alarms;
"To prevent overflow of fuel during the filling of tanks, by a control signal to turn off the pump switch (off), sound and light alarms;
"Displays the results of measurement and calculation of parameters on a standalone display, or (ii) output to the user's computer via standard interface RS-232C, RS-485, USB;
"Metrological calibration without removing the equipment;
"Significant reduction in downtime for the transfer station change;
"Transfer of measured data on the cell phone user and a remote computer over the GSM 900/1800;
"Transfer of information on the state of security and fire alarm monitoring system for GSM tanks.
Information about newness of the development:
there are inventor's certificate -- 3 items
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|