RTD SIGNAL CONVERTER OF SENSOR SDI-TC
Purpose of the development:
Designed to work with environmental sensors and RTD SCI TSP to convert RTD signals into standard 4-20 mA signal.
Recommended application field:
instrumentation
Technical characteristic:
- Voltage DC - 8-30;
- Normalized output signal - 4-20 mA;
- The maximum load resistance - 0.02 Ohm;
- Limit of acceptable basic error - +/- 0.25%;
- Limits of additional error caused by the temperature change - +/- 0.05% / 0C.
The development stage readiness:
Introduced in production
Description of the development:
() The converter is mounted in the sensor head. The resistance of the sensor is converted into a standard output current directly proportional to the measured temperature.
corresponds technical description
Conforms to technical characteristic
Possibility of transfer abroad:
Licence's sale Technological document's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|