OCTANE METER SVP 2.00.000


Purpose of the development: Is intended to define the mark and measuring the octane number of gasoline, diesel fuel cetane number, pour point estimates Dees fuels determining dielectric loss tangent of transformer oil.

Recommended application field: Gas stations, refineries, tank farms, oil storage, customs, environmental, monitoring organizations, power stations, as well as for process control in the manufacture of gasoline, fuels and diz reclaimed motor oil.

Technical characteristic: Range of measured octane numbers, units. RON 40-120 Maximum permissible error of measurement of octane numbers, units. Octane, no more than 0.5 Limit of acceptable difference between parallel octane number measurements, units. Octane, no more than ± 0.2 Measuring range of cetane numbers, units. CN 20-100 Maximum permissible error of measurement cetane number units. CN, no more than ± 1.0 Limit of acceptable difference between parallel dimensions cetane numbers, units. CN, no more than ± 0.5 The measuring range of engine oils purity,%, no more than 95 Maximum permissible error of measurement of the degree of purification motor oil,%, not more than 0.1 Limit of acceptable difference between parallel measurements of the degree of purification motor oil,%, not more than 0.01 The measuring range of the dielectric constant fuel, meals, 1-5 Maximum permissible error of measurement of the dielectric constant, ed., Not more than 0.001 Limit of acceptable difference between parallel measurements of the dielectric constant of petroleum products, ed., Not more than 0.001 Measuring range of the breakdown voltage of transformer oil (dielectrics), HF 5-100 Maximum permissible error of measurement of breakdown voltage transformer oils, HF, no more than 1 Limit of acceptable difference between parallel measurements of breakdown voltage transformer oils, VA, not more than 0.2 The measuring range of loss tangent of transformer oil, 0.01-5% Maximum permissible error of measurement of loss tangent of transformer oil,%, max. 0.01 Limit of acceptable difference between parallel measurements of the loss tangent of transformer oil, ed., Not more than 0.001 Time measuring 1-5 Threshold indication of malnutrition, in (on battery power) 5.4 Dimensions, mm • gauge 60 x 100 • electronic control unit 100 x 200 x 60 Octane Weight, kg, not more than 0.9 Time to failure, h, at least not less than 1000.

Advantages over analogues: Octane SVP 2.00.000 surpasses all foreign and Russian counterparts, as it allows to analyze the gasoline with any additives, and also has the ability to create individual program of measurements, the device is configured to any gasoline.

The development stage readiness: Introduced in production

Description of the development:
()
Features of the device: Determination of octane gasoline; Determination of cetane number of diesel fuels; Evaluation of the pour point diesel fuels; Definition of quality and purity of motor and industrial oils; Measurement of the breakdown voltage of transformer oil; Determination of the dielectric loss tangent of transformer oil; Measurement of the dielectric constant of petroleum products; The new modification of the universal quality analyzer of petroleum products is designed to determine the make and measure the octane number of gasoline, cetane number diztopliv, as well as to assess the freezing temperature diztopliv, quality and purity of motor, industrial and transformer (dielectric breakdown voltage) oils. In this modification implemented more accurate measurements using the correction digital thermometer depending on the temperature of the test sample. The oil quality analyzer memory can store measurements and transfer them to a PC. Ability to create individual measurement program (optional) allows you to configure the device to determine the quality of absolutely any gasoline, and therefore its use in all countries of the world. With the help of a computer device allows quick and easy measurements and correction, save the data in a format txt or xls. The device has an additional AC power supply 220 W, the LED battery power, the display backlight. The device is recommended for use at filling stations, oil refineries, customs, environmental, regulatory organizations, power stations as a portable universal tool for quality control of fuels and lubricants.

corresponds technical description
Conforms to technical characteristic

Possibility of transfer abroad:
Licence's sale
Technological document's sale
Realization of finished commodity

Photo

Country Russia

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: