TARGETED FIRE ALARM SYSTEM "FOTON-A"


Purpose of the development: The system is designed to address and unnumbered automatic fire detection by factor - smoke, fire, temperature - and manages firefighting, smoke, ventilation, air overpressure, elevators, alarm, fire doors, technological processes, etc. in areas of industrial facilities, buildings of all types, including buildings increased -rise and high-rise buildings, warehouses, retail and hotel complex, offices, river and sea vessels and other facilities. The system provides simultaneous transmission of information to other management systems automatic fire.

Recommended application field: In the fire safety system.

Technical characteristic: Specifications: --- 50 Hz power supply 220 from the main network 24 of the reserve network; --- Automatic switching networks (primary-backup); --- Automatic charger; --- Integrity monitoring power lines U = 24 B; --- Continuous operation; --- An autonomy of 72 hours.

Advantages over analogues: Fire Alarm System Address "Photon-A" control function means fire protection of buildings and structures - is a next generation system, the corresponding the European standards series EN-54 standards and Ukraine. The system has a certificate of compliance with state system UkrSEPRO and certificate Ex-TCCExEE and Type Approval Certificate of Russian Maritime Register of Shipping.

The development stage readiness: Ready for application

Technical and economic effect: System "Photon-A" is: - A flexible distributed information management system, fire alarm system; - Fire detection by factors: the smoke, the temperature of the flame; - A set of detectors: smoke, heat, flame and hand in plastic and metal body; - Degree of protection IP20, IP22, IP30, IP32, IP40, IP55 provides device design, block detectors; - Explosion-proof: detectors and interface unit, insulators and consoles BOB-AB have the form Ex - intrinsically safe circuits "IExIbIIBT5 complete with BUS" when using the unit BUS, it can be used in hazardous areas, Class B-1, B-1a and B-1b, B-1g, BII, BII-a, in accordance with Section 4 DNAOP 0.00-1.32 "Electrical Code. electric special installations"; - The maximum number of addressable devices serviced - up to 63 trains to 63 addressable devices; - Enable-disable external devices: smoke removal, ventilation, elevators, process control (Switching power circuits - 220 at current 6A); - Management of gas, powder and aerosol fire (up to 8-way); - More than 30 service and service modes; - Multi-level password access to the service and the service mode; - The use of unshielded cables.

Description of the development:
()
The system has a wide range of functions performed: - Continuous monitoring of performance of devices and their components; - Self-diagnosis devices, power systems and alarms; - Auto-tuning the sensitivity of smoke detectors; - The ability to combine up to 30 systems in the total PC; - Display information about the fires to the printer with their characteristics; - The creation of up to 256 zones of control external devices with the issuance of the relay control signals.

Information about newness of the development:
there are inventor's certificate -- 1 items

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: