SMOKE PROTECTION SYSTEM


Purpose of the development: Smoke protection system - a complex of technical means for Forced removal of smoke from the rooms and how the evacuation of buildings in case of fire. Automatic control system of technical means of smoke protection is based on the components of the targeted fire alarm "Photon-A" allows the following functions: --- Include notification of the fire; --- Include exhaust ventilation system; --- The fan air overpressure; --- Flame-retardant control valves; --- Operate lifts in the "FIRE".

Recommended application field: Fire safety system.

Technical characteristic: For smoke protection system uses detectors IPL - Fire Heat locomotive - designed for acquisition and information fire on the locomotive and other objects when the ambient air above the permissible value. Activation temperature of 100 ° C to 110 * C *, giving the signal is contact opening.

Advantages over analogues: System "Foton-A" when triggered automatic fire detectors installed within the protected area, which are issued by triggering signals of fire, forms command signals to turn off equipment and ventilation systems, the activation of the executive smoke protection equipment, backwater vozduha.Upravlenie system is in automatic or manual mode with fire post on push-button stations, installed at the emergency exits. Service life - 10 years manufacturer's warranty - 2 years.

The development stage readiness: Ready for application

Description of the development:
()
To address control on, the fan exhaust ventilation system control the opening (closing) shutters fire, elevator control on commands control unit PU (PU-A1 or IP-A1PT) transmitted on the interface RS485, used Relay peripherals BRVU-A24, part of a system of targeted fire alarm "Photon-A." Shield storey Type I is intended to bring one address plume issuing control signals to the fire dampers, valves, monitoring, control, push-button stations. Valve operation is carried out on the device IP commands transmitted the interface. Shield storey Type II is designed to enhance control and monitoring signals shield type I. When triggered fire alarms to CP audible signal and light panel "Fire", The display shows the location of the activated detector (floor apartment) and the number triggered detectors, their type. To display the locations of sensors, information on opening valves and all information the system as a whole is intended mimic. It is produced for each object individually through a set of modules of the controller, power indication. Has a built-in power backup.

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: