CENTRAL STATION OF ROUND THE CLOCK MONITORING UCS-1000


Purpose of the development: Central Station clock monitoring UCS 1000 is designed to provide a flexible system of centralized patient monitoring using wired and wireless data transmission technologies, the creation of an electronic database of medical records of patients, as well as the ability to connect to a local hospital information system. Central Station IOM provides: • receiving, processing, and real-time visualization of the wave curves and numerical information on the status of patients coming from the bedside monitors YM-300 and telemetry devices; • Creating and maintaining a database of all patients; • Remote control of all functions bedside monitors, including changes in levels of alarm and priority; • connection to the hospital network; • the ability to view data from patient monitors on a remote computer; • connection to the paging system of alarm; • the ability to view data from patient monitors another central station connected to the network; • the ability to connect a remote display; • support for display on 2 high-resolution display (1280x1024) with an arbitrary choice of the display configuration for each display; • a centralized multi-level alarm for each patient individually with the priorities for each parameter; • Reading accumulated bedside monitors information after temporary disconnection from the central station; • access to information from a bedside monitor to another monitor of connections to a central station; • preservation of patient information, data monitoring and processing results in an individual file; • recording, viewing, analyzing and documenting trends for the duration of monitoring the patient; • automatic detection of arrhythmias and maintaining 20-second ECG on each episode arrhythmias; • automatic arrhythmia analysis by type of arrhythmias, frequency and time of appearance; • Ongoing analysis of ST-segment shift on all leads; • the possibility of recording an electrocardiogram (single file) for 96 hours and then view and advanced analysis; • a detailed analysis of ECG and heart rate variability; • Automatic registration and maintain a database of critical events during the time of monitoring the patient; • calculation of the dose and rate of administration of medicines; • print the results of monitoring in the form of tables, graphs, ECG fragments.

Recommended application field: Medicine.

Technical characteristic: Features: The possibility of simultaneous monitoring and real-time processing of information from 64 monitors The possibility of simultaneous visualization on one screen of information from multiple monitors Display numerical parameters, and at least two wave curves for each instrument Mapping (visual and audio) of all alarms and priorities arising on bedside monitors Displays the trend of short (up to 4 parameters for the last 10 min.) Displaying current FAR The ability to store 20 ECG The ability to store 96 hours of ECG recordings Possibility of ECG from the monitor and entering them into the database Getting out of the monitor trends (last 96 hours) and entering them into the database The ability to store in the database parameters of HRV Viewing, recording and export records in Excel Statistical analysis of trends Trending on the parameters of HRV The possibility of identifying and editing the current patient and medical history Ability to print ECG to the laser and thermal printers The possibility of remote control of connected devices Saving and viewing of all events recorded by each monitor Opportunity HRV analysis (review, analysis and documentation) 96 h ECG recordings (in accordance with the methods of processing Holter recordings) An enhanced ECG analysis (viewing, ECG analysis, trends, and documenting violations) 96 hour ECG recordings (in accordance with the methods of processing Holter recordings) Calculator dose and rate of injection syringe dispenser (formulas according to user instructions for syringe dispenser IVAC TCI & TIVA firm ALARIS) Calculator doses of medications, expressed in tablets, liquids, drops (formula in accordance with the procedure for nurses hospitals USA) Electronic list of assignments (like on the need for a drug, indicating the dosage and method of entry, and the holding of a procedure) Archive patient record The ability to view recorded events CA Ability to send messages to the remote alarm medical staff

Advantages over analogues: New features centralized clock monitoring of patient safety. Central Station UCS 1000 provides reception, analysis and documentation of real-time information on status of patients coming from the bedside monitors YM-300, and allows for continuous control of basic parameters of life.

The development stage readiness: Ready for application

Technical and economic effect: Central Station UCS 1000 is equipped with diagnostic software modules, which allows not only to carry out continuous monitoring of the patient, but also to evaluate the efficiency and optimality of activities, which brings the healing process to a new level.

Description of the development:
()
Central Station UCS 1000 is a powerful computer with one or two color displays (diagonal of at least 17), with an audible warning sound system (alarm), a laser printer and thermal printer. The central station is connected to the bedside monitor (maximum - 64 Monitor) with speed pomehozaschitnogo interface. Central station with wireless realized through WiFi-technology. Local wireless network is easy to solve the problem of connecting new monitors, eliminating the need for cables and is an economical and effective alternative to traditional cable system. The central station has advanced network for sharing data and can be incorporated into a local health facility network (Ethernet). In this case, the in-hospital database (X-ray, tomography, ultrasound, lab results, etc.) available to users of the station, and can be used for further consultation and diagnosis.

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: