THERMAL CONDUCTIVITY
Purpose of the development:
Thermal Conductivity designed for materials testing. The main application of the heat meter - the definition of thermal conductivity of building materials and insulation of buildings, pipelines, etc.
Recommended application field:
Construction.
Technical characteristic:
ITP-meter heat MG4 "probe" is designed for rapid measurement of thermal conductivity of materials during their production and use, as well as a survey of buildings.
- Measuring time is not more than 10 minutes.
- Automatic archiving of test results, including the date and time.
- Non-volatile memory of 100 measurements.
- The range of 0.03 ... 1.0 W / m · K.
- Rel. measurement error of ± 7%.
- Weight 0.5 kg.
ITP-meter heat MG4 "probe" is included in the state register of Russia, Ukraine, Belarus and Kazakhstan.
Advantages over analogues:
Thermal Conductivity MIT-1 has an additional battery power supply, which allows working with the instrument in the field for 10 hours without recharging.
The development stage readiness:
Introduced in production
Description of the development:
() Thermal Conductivity MIT-1 for rapid determination of thermal conductivity (range: 0.03 ... 2 W / m * K) of a wide range of building materials probe method in accordance with GOST 30256-94 with their quality control. MIT-1 device is included in the state register SR RF.
Measuring the thermal conductivity of the ITS-1 is designed to determine the thermal conductivity (range 0.02 ... 1.5 W / m * K) and the thermal resistance of a wide range of building and insulation materials stationary method in accordance with GOST 7076-99 under the control of their quality. Dimensions of test specimens 150 * 150 * 4 ... 40 mm. ITS-1 device is included in the state register SR of Russia and Belarus.
ITP-meter heat MG4 "100" is used to determine the thermal conductivity and thermal resistance of the material at a sample temperature +15 ... 42.5? C. Provides automatic temperature control and temperature control of the sample. ITP-meter heat MG4 "100" has a non-volatile memory of measurements, real time clock and data transfer mode on the PC. Thermal conductivity measurement range 0.02 ... 1.5 W / m K, the thermal resistance of 0.01 ... 1.5 m2 · K / watt. Dimensions of the test specimen: 100h100h3 ... 28 mm. The relative error of ± 5%. Optionally equipped with a thermal probe (probe cost 11,800 rubles.). Weight 4kg. ITP-meter heat MG4 "100" and is included in the state register of Russia, Ukraine, Belarus and Kazakhstan.
ITP-meter heat MG4 "250" is used to determine the thermal conductivity and thermal resistance of the material at a sample temperature +15 ... 42.5? C. Provides automatic temperature control and temperature control of the sample. ITP-meter heat MG4 "250" has a non-volatile memory of measurements, real time clock and data transfer mode on the PC. Thermal conductivity measurement range 0.02 ... 1.5 W / m K, the thermal resistance of 0.01 ... 1.5 m2 · K / watt. Dimensions of the test specimen: 250h250h5 ... 50 mm. The relative error of ± 5%. Optionally equipped with a thermal probe (probe cost 11,800 rubles.). Weight 16kg. ITP-meter heat MG4 "250" is included in the state register of Russia, Ukraine, Belarus and Kazakhstan.
corresponds technical description
Ready for implementation
Possibility of transfer abroad:
Licence's sale Technological document's sale Creation of joint enterprise Realization of finished commodity
Photo
Country
Russia
For additional information turn to: E-mail: gal@uintei.kiev.ua
|