Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

THE HYDROCARBON ANALYZER IN WATER TD-4100


Purpose of the development: TD-4100 is used for the control of treated and untreated sewage, industrial wastewater, groundwater, process water, drinking water water lines, storm tides.

Recommended application field: Ecology. Waste management.

Technical characteristic: Technical characteristics Measuring range 1 ppb - 1000 ppm (depending on the origin of the water and the desired organic compound) Overall dimensions 1118 * 1094 * 275 mm Weight 29 kg Resolution internal display ppm, ppb, depending on the signal Managing touch keyboard Power supply 110 - 240 V, 50/60 Hz, 2A, 24 - optional Requirements for connection? '' MNPT (standard) or? '' Pipe. Return: 2'' Drain Sample Pressure Input: 0.5 - 2 gpm (2 - 8 l / min) 5 - 20 psig (34 - 138 kpag) Optional - sample pump Return: atmospheric pressure (optional - return pump test) The sample temperature is not more than 60 C (material connectors - PVC) Up to 95 ° C with connectors made of stainless steel (optional) Requirements for air supply 15 SCFH at 10 - 20 psig The ambient temperature 0 - 49 C (optional - heater or cooler Vortex) Characteristics of the cell flow: Non-contact cell with blowing The principle of measurement of UV - fluorescence Signal Stability ± 10% at 6 months. Response Time Less than 10 seconds Calibration Standard additive or correlation with standard methods Reagents not applied Alarm threshold 2: early warning / upper threshold + internal failure Alarm contact A / C (Optional - dry contact) Output 4 - 20 mA The communication protocol Optional: Hart, Modbus Self Diagnostics, internal failure with alarm output relay and display Security Password protection, lockable case The electronics housing FRP Category IP 66, NEMA 4 X Replacing the lamp twice a year; periodic cleaning compounds Certificates IMO MEPC 107 (49), 60 (33), ISO 9001 manufacturing

Advantages over analogues: TD-4100 analyzer can reliably control the content of benzene, toluene, xylene, gasoline, diesel oil and other petroleum products in water. TD-4100 - on-line continuous analyzer that does not require frequent maintenance, providing monitoring and petroleum hydrocarbons with a sensitivity at the level of ppb Continuous on-line monitoring using TD-4100 provides effective feedback to the measurement of hydrocarbons in water. The device makes it possible not only to measure, but effectively manage the processes of treatment and disinfection of hydrocarbons. Compared with laboratory analysis of on-line continuous monitoring provides an effective distance, independent of the operator's measurement of petroleum products and other hydrocarbons in the water. .

The development stage readiness: Introduced in production

Description of the development:
()
Non-contact cell non-polluting. The unit is missing the glass cell. Hydrocarbons are detected in a stream of water that flows through the open cell. The water does not contact with the optical window, whereby it remains clean. The patented air curtain protects the optical window from fogging in humid atmospheres of hot water. Maintenance free In the device no need to replace the tubes, pumps and valves. Routine maintenance includes replacing the lamp twice a year. Checking the system by using a standard sample CheckPoint ™. To correctly install the sampling system for trouble-free operation. Direct continuous monitoring. The analyzer continuously monitors the flowing stream of water. For process monitoring hydrocarbon in water required chemicals, sample preparation, handling and mechanical mixing of the sample. The high sensitivity and selectivity Sensitivity Benzene, toluene, xylene, gasoline, crude oil, and aromatic petroleum solvents detecting device in the range of ppb (g / l) to ppm (mg / l). For example, TD-4100XD analyzer can measure the diesel fuel 1 ppb in water without the problem of cross sensitivity. Selectivity TD-4100 analyzer measures the amount of hydrocarbons in water by fluorescence. Fluorescence occurs when a molecule absorbing light at a specific wavelength, whereupon light is emitted with higher wavelengths. High accuracy TD-4100 provides direct measurement of the fluorescence of hydrocarbons in the water with an accuracy corresponding to laboratory analysis.

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: