Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

HIGH VOLTAGE STANDS SVP-05 AND SVP-05TS


Purpose of the development: Stand mobile high-SVP-05 is designed for burning a defective cable insulation with subsequent afterburning High Voltage Stand SVP-05TS is designed for burning (destruction junction with resistance close to zero, in-circuit phase conductor high voltage cable on the shell / phase conductor) a defective power cable insulation, followed by its afterburning, to eliminate the contact resistance at the site of the defect, it can be used known methods for determining the distance to a cable fault and the fault location directly on the track cable lines.

Recommended application field: Energy.

Technical characteristic: The parameters of the stand SVP-05: Parameter Value Mains voltage single-phase alternating current, 220 ± 20 Frequency, Hz 50 ± 2 Current, A, no more than 80 Kilovoltmeter measuring the high DC voltage 0 ... 25 Weight, kg, not more than 110 Average service life, years 10 Technical data of the stand SVP-05TS: Parameter Value Mains voltage single-phase alternating current, 220 ± 22 Frequency, Hz 50 ± 1 The maximum output voltage at idle, 25 kV The number of working stages, pcs. 6 The maximum output current under short-circuit for high-speed, A, not less than 7 The maximum output current under short-circuit protection for low-voltage stage, "500", A, at least 15 The highest uptime, min load current: 100% of the maximum 10 70% of maximum 30 Current, A, no more than 40 Average service life, years 10 Overall dimensions, mm, no more 820x630x500 Weight, kg, not more than 185

Advantages over analogues: Operating conditions SVP-05: The device is designed for use indoors or under a shed in the following conditions: parameter Value Ambient temperature, ° C from -20 to +40 Relative humidity,%, not more than 80 at +20 ° C Barometric pressure, kPa (mm Hg. Cent.) 84.0 - 106.7 (630 - 800) The wait staff person at least 2 Operating Conditions SVP-05TS: The device is designed for use indoors or under a shed in the following conditions: parameter Value Ambient Temperature, ° C -10 to 40 Relative humidity,%, not more than 80 at a temperature of +25 ° C Barometric pressure, kPa (mm Hg. Cent.) 84.0 - 106.7 (630 - 800)

The development stage readiness: Introduced in production

Description of the development:
()
Scope of supply: name Number Stand high-SVP-05TS 1 The key to the lock box Documentation - Passport SVP-05TS 1

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: