INSTALLATION OF MEASUREMENT A BREAKDOWN VOLTAGE OF TRANSFORMER OIL UIM-90M
Purpose of the development:
Installation of measuring oil UIM-90M is designed to determine the breakdown voltage of transformer oil and other liquid dielectrics in accordance with GOST 6581-75 and other standards.
Recommended application field:
Energy.
Technical characteristic:
Technical data:
parameter Value
Mains voltage single-phase alternating current, 220 ± 22
Frequency, Hz 50 ± 2
The highest breakdown voltage (rms), 80 kV
The relative error in the voltage measurement,%, not more than 3
The volume of the measuring cell, 400 cm3
The highest power consumption, kVA 0.5
Weight, kg, not more than 26
The average life of the product, 6 years
The development stage readiness:
Introduced in production
Description of the development:
() Scope of supply:
name Number
Installing the UIM-90M 1
Measuring cell 1
Remote Control 1
1 cable network
Fusible links RF1 5x20mm, 5 A
Template caliber 1
Packing box 1
Measuring cell Yai-80 Option
Documentation - User Manual 1
Metrological certification of GP "Kharkivstandartmetrologiya" Optional
Terms of use:
Mashines is targeted for use in the laboratory, the capital of residential premises or in the premises of this type under the following conditions:
parameter Value
Ambient Temperature, ° C +10 +35
Relative humidity,%, not more than 80 at a temperature of +25 ° C
Barometric pressure, kPa (mm Hg. Cent.) 84.0 - 106.7 (630 - 800)
corresponds technical description
Ready for implementation
Possibility of transfer abroad:
Licence's sale Licence's sale Technological document's sale Creation of joint enterprise Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|