TESTING DIODE DEVICE - AID-70/50
Purpose of the development:
AID-70/50 diode test apparatus designed for testing the insulation of power cables and solid dielectric DC voltage 70 kV, as well as for testing of solid dielectrics sinusoidal voltage with frequency of 50 Hz in the range of 50 kV.
Recommended application field:
Energy.
Technical characteristic:
Specifications AID-70/50:
AID 70/50 has a supply voltage of single-phase alternating current, V - 220 + - 11;
Options AID 70/50 on the rectified voltage in continuous operation at rated voltage:
- Maximum operating voltage, kV - 70;
- Maximum operating current, mA - 12;
Options AID 70/50 on the AC voltage in continuous operation at rated voltage:
- Maximum operating voltage (rms) kV - 50;
- Maximum operating current (RMS), mA - 20;
Options AID 70/50 on the AC voltage in intermittent duty cycle mode (MF) 17% and cycle time of 6 min. at nominal voltage:
- Maximum operating voltage (rms) kV - 50;
- Maximum operating current (RMS), mA - 45;
Other options AID 70/50:
- Power consumption, kW, not more - 3;
- Weight, kg, not more than:
- Control unit - 14;
- High voltage unit - 35;
Average service life, years - 10.
The development stage readiness:
Introduced in production
Description of the development:
() The unit test AID-70/50 diode is designed for operation under a canopy or indoors at working temperatures from -10 ° C to 40 ° C, 80% relative humidity at a temperature of 20 ° C and atmospheric pressure of 84.0 - 106 , 7 kPa (630 - 800 mm. Hg. cent.).
Completeness AID - 70/50:
- Control unit - 1;
- High voltage unit - 1;
- Network cable - 1;
- Wire grounding - 2;
- Insert fuse VP2 -1, 2.0 A - 2;
- Insert fuse VP3 -1, 10.0 A - 2;
- Manual - 1;
- Metrological certification of the State Enterprise "Kharkivstandartmetrologiya" - 1.
corresponds technical description
Ready for implementation
Possibility of transfer abroad:
Licence's sale Licence's sale Combinated reduction to industrial level Creation of joint enterprise Realization of finished commodity
Photo
Country
Ukraine