ATOMIC EMISSION SPECTROMETER CMEA - 30


Purpose of the development: Предназначен для измерения в жидких пробах концентрации химических элементов, допускающих спектральный эмиссионный анализ.

Recommended application field: Scope - measuring equipment, spectral analysis instrument to perform the following tasks: - Analysis of ultrapure substances on content of trace - Monitoring the quality of drinking water - Determination of the mass concentration of toxic elements in natural and waste waters at the MPC and below - Various applications in medicine and where there are restrictions on the amount of sample required for analysis - Analysis of chemical elements that are not defined or poorly defined methods of atomic Absorption such as C, B, Si, S, P, Se, J (KJ) - Analysis of the rare earth elements: Eu, Dy, Sm and others.

Technical characteristic: TECHNICAL SPECIFICATIONS: - The spectral range from 200 to 830 nm - Spectral resolution - better than 0.05 nm - Absolute wavelength deviation from the set value - not more than 0.05 nm - Detection limit of copper - 0.1 mg / l - The measurement range of the mass concentration of copper in the solution - from 1 to 1000 mg / l - The limit of acceptable standard deviation of the random component of relative error measuring the mass concentration of copper in the solution in the range from 10 to 1000 mg / l - not more than 10% - Relative linearity of the calibration characteristics of copper ranging from 10 to 1000 mg / l - within 10% - Stability of the calibration curve within one hour after graduation - in the range of 10% - Powered by 220 V - Power consumption - no more than 300 watts.

Advantages over analogues: ADVANTAGES: - High sensitivity of chemical elements along with low background signal and idler - High dynamic range (at least three orders of magnitude) - The possibility of independent regulation of the temperature of drying, ashing, atomization and energy of free electrons - The presence of the registration regime - frequency of the modulated signal, in which practically disappears backlighting - Possibility of controlling the pressure and flow quantity of helium in the atomizer - A small quantity of the sample - up to 10 microliters. Automatic dosing and application samples - The ability to automatically adjust the output and greater accuracy on a given spectral line - Cost of food and consumption of helium - 1 can (40 liters, 150 atmospheres) for at least six months of the spectrometer - No flammable gases - helium working gas (argon can work) - No additional spectral lamp measurement of various elements - monochromator calibration over the entire spectral range from 200 to 830 nm is carried out by a spectral lamp iron.

The development stage readiness: Introduced in production

Description of the development:
()
Work spectrometer based on a completely new, having no analogues in the world, the source of the spectrum with non-self discharge. Structurally spectrometer combines: an optical block electronic, computing complexes, the pump foreline, bottle with an inert gas. The essence of a fundamentally new method of obtaining the spectrum is non-self-excitation of the gas discharge by means of electron pairs in the dry residue of the liquid sample being analyzed, pre-translated into atomic vapor thermal heating. Atomization takes place under inert gas (helium or argon). For atomic vapor uses a spiral tungsten cathode - atomizer, which is also the source of thermal electrons. Using the original source of the spectrum in the device reduces the intensity of the continuous background and, as a consequence, greatly reduces the limit of detection elements analyzed in comparison with classical methods atomic emission and atomic absorption. The main part of the spectrometer is the atomization chamber with windows made of quartz glass for the output radiation at a monochromator, hatch for automatic feeding of the sample and the window for observation. The camera is mounted on a special table that provides spatial adjustment. The analysis is as follows. The sample with an automatic dispenser (automatic feed samples) applied to the cathode of the spiral - the atomizer. By heating the cathode electrical current carried drying and, if necessary, "digestion" of the sample in vacuum or in an atmosphere helium. Then the chamber is filled with helium to a predetermined pressure and produce a pulse heating to a temperature katoda- atomizer in the range 2000-3000 degrees C. Liquid helium consumption at the same time - 0.2 .... 0.4 cubic dm. for analysis. Recommended grade A helium (helium mass fraction 99.995%). The most distinctive chemical elements, measured using copper, zinc, cadmium, lead, nickel, chromium, manganese, cobalt, arsenic, calcium, magnesium, potassium, sodium, aluminum, titanium, cesium, dysprosium, europium, gallium, indium, lithium, and others. In addition, it registers SEV-30 trace nonmetals, such as carbon, iodine, silicon, phosphorus, sulfur. these elements atomic - absorption devices are not measured. Measuring the concentrations of heavy metals in the sample produced by the exhaust agreed methodologies and industry Activities. Standard samples of solutions of metals are not included.

corresponds technical description
Conforms to technical characteristic

Possibility of transfer abroad:
Licence's sale
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: