Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

SPECTROMETER OF GAMMA RADIATION ENERGY SED-001M "AKS-S"-TPO


Purpose of the development: Spectrometer gamma radiation energy type SED-001m "AKP-S"-TPO is designed to determine the isotopic composition and the activity of gamma-emitting radionuclides unsorted solid radioactive waste (SRW) the first and second groups of passive method (without sampling).

Recommended application field: Control of radiation safety.

Technical characteristic: Selected radionuclide composition : 137Cs, 134Cs, 60Co, 58Co, 54Mn, 59Fe, 124Sb, 51Cr, 110mAg. Range of gamma radiation , MeV 0.2-2 . The relative energy resolution for the 661.66 keV , % : 7.5 % - 9 %. Maximum permissible error of activity measurement geometry " Marinelli 1 l ",%: ± 25. The minimum measurable activity (at 95% confidence level over the measurement time of 10 min) for a radionuclide not more kBq : by 137Cs -20, for 60Co - 10. The maximum permissible errors of measurement of total activity , P = 0.95 %, max : 45. Maximum permissible additional error measurement of the activity caused by the change in power supply voltage in the range of 220 ± 22 ,%: ± 5 . Number of channels: 1024. Setup time , min: 30. Time of continuous work , hours : 24. Food / Hz : 220/50 .

Advantages over analogues: Installing SED-001M "AKP-S"-TPO is suitable for measurement of objects of almost any shape without sampling. Allows you to optimize the SRW. System calibrations performed by the author's method, implemented in software.

The development stage readiness: Introduced in production

Description of the development:
()
Determination of the isotopic composition and activity of radioactive solid waste unsorted groups 1 and 2 : - In the primary packaging (bags ) in the field of radioactive waste; - Placed in metal containers of various shapes and sizes on the collection sites ; - In containers before being sent to storage. Setting determines the isotopic composition of gamma -emitting radionuclides , the activity of which exceeds 1 % - 2 % of the total activity measured solid radioactive waste ( SRW) . Ingredients: - Multi-channel pulse analyzer " AMA -P -09 " - Scintillation detection unit BDEG 40 - A12 - Protection for BDEG 40 - A12 and collimator - Laptop - Ultrasonic Locator with Laser Sight - Rack mounting blocks spectrometer - Dosimeter to assess the radiation dose - Software AkWin/AK1-P - Methods of measurement " Solid radioactive waste . Activity and isotopic composition . Typical methods of execution - measurements using scintillation spectrometers and software AkWin/AK1-P . "

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Licence's sale
Technological document's sale
Creation of joint enterprise
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: