Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

LASER THERAPEUTIC APPARATUS "QUANTRON-LASER - 01,02"


Purpose of the development: «QUANTRON-LASER - 01,02» - small two-channel digital new generation therapeutic devices that are designed to: - The treatment of low-intensity laser radiation of semiconductor lasers through exposure to appropriate areas (tissues, organs, nerve endings) of a number of diseases; - Scientific research in the field of laser medicine.

Recommended application field: - Dermatology (dermatitis, skin lesions erosive ulcers, neurodermatitis , herpes , etc.). - Otolaryngology ( otitis externa , otitis media , chronic tonsillitis, chronic pharyngitis , sinusitis ). - Dental (diseases of the oral mucosa and periodontal stomatitis, alveolitis , jaw fractures ). - Neuroscience ( lumbago, plexitis , trigeminal neuralgia ). - Gynecology ( salpingitis , bartholinitis , erosion and pseudo cervical colpites , tsertsivity kraurosis and vulvar itching , cracked nipples , etc.). - Urology (acute and chronic prostatitis , acute epididymitis, acute and chronic pyelonephritis ). - Proctology (hemorrhoids , anal fissures ). - Cardiovascular disease (ischemic heart disease , angina, hypertension disease ). - Diseases of the musculoskeletal system ( osteochondrosis deformans , epikondility , bursitis , tenosynovitis , nonspecific polyarthritis, heel spurs ). - General physiotherapy and reflexology.

Technical characteristic: Emission wavelengths of semiconductor laser emitters nm: Red - 650 ; Infrared - 870 ± 20 . Radiation power at the output of the main fiber ( installed ) , MW : red - 0/2/6/9/20 ; Infrared - 0/25/50/75/100 . Fixed frequency amplitude modulation of the radiation , Hz : 0 ( continuous generation ) 9.4 / 300/1000 . Programmable frequency mode of action , Hz 0,5-10000 . The installation procedure , min / s : 0 s .... 99 minutes and 59 seconds . % Modulation depth of the constant component of the signal : 25/50/75/100 . Power consumption, W : not more than 5 . Power supply: 220V, 50Hz . Laser Hazard Class : 3 .

The development stage readiness: Introduced in production

Description of the development:
()
Devices allow intravenous and percutaneous irradiation of blood. Phones have built-in display program failure, as well as by visual inspection procedure parameters for each channel. Available as independent and common modes of lasers (the latter is ensured by using a special fiber unification). Trunk interface provides a complete set of connection rigid and flexible fiber-optic tips for physiotherapy.

corresponds technical description
Conforms to technical characteristic

Possibility of transfer abroad:
Licence's sale
Technological document's sale
Creation of joint enterprise
Joint production, sale, exploitation

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: