INDICATOR OF CONTINUOUS FLOW (ICF-1)
Purpose of the development:
Indicator of continuous flow ICF-1 is designed for continuous monitoring of continuous flow of liquid (eg for monitoring the presence of water in gasoline, water in the DT).
Recommended application field:
Refining industry, chemical industry.
Technical characteristic:
1. Power supply, no more than 30 VA.
2. Nominal diameter of the sensor: 25 mm.
3. Overall dimensions, not more:
- Sensor - 250 * 100 * 52 mm;
- Measuring device - 300 * 200 * 445 mm.
4. Weight, not more:
- Sensor - 2.5 kg;
- Measuring device - 5 kg.
The development stage readiness:
Pre-production model is made
Description of the development:
() ISP- indicator comprises one of a sensor and a measuring device. The sensor has a flameproof , and the measuring device - airtight . The sensor is mounted directly on process piping through the bypass . The maximum distance from the sensor to the measuring device up to 200 meters or more ( on request) . The principle of continuous flow control - Optical .
ISP- indicator 1 has flashers , which indicates the presence or absence of water at a controlled flow of a liquid ( gasoline , diesel fuel , oil , etc.) and a device generating a signal in the presence of water the local automation system which is designed to switch off the pump automatically control valves and process piping etc.
corresponds technical description
Conforms to technical characteristic
Possibility of transfer abroad:
Licence's sale Technological document's sale Combinated reduction to industrial level Joint production, sale, exploitation
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|