SWITCH MODULES CM / TEL WITH A VACUUM BREAKER BB / TEL-10 FOR MODERNIZATION OF CSR IN THE PRODUCTION OR FACTORY
Purpose of the development:
Switch Modules with vacuum switches BB / TEL-10 are intended for the reconstruction of chambers of stationary unilateral service CSR (CSGN) oil circuit breakers with EMG-10, EMG-133, MEP, VMP-10 and others. In terms of the customer.
For cameras stationary unilateral service type:
CSR-266
CSR-272
CSR-285
CSR-292
CSR-298
CSR-366
CSR-393
CSR-2200
CSR-2U
CSR 2UM
CSR 2UMz
D-13B
CP-03-00
LP-318
uFV
MKFN
VI-K
W-153
W-163
W-164
W-190
W-191
W-195
W-204
SCC-II-10
SLV-III-10
SCC-VI
KRN-10
YAKNO
2KVE 6
Technical characteristic:
Main specifications:
Parameter Rated breaking current (kA) / rated current (A)
12.5 / 630;
20/630;
20/1000 20/1600 25/2000 **
31.5 / 2000 **
Rated voltage 10 kV
Rated current, A 630; 1000 1600 2000
Rated breaking current kA 12.5; 20 20 25; 31.5
The current withstand, kA (peak value) 32; 51 51 63; 80
Withstanding thermal current, 3 sec., KA 12,5; 20 20 25; 31.5
Rated breaking current of single capacitor bank 800 A
Power frequency test voltage, 42 kb
Mechanical operations, operations-0, at least 50,000 (150,000 *) 30000 30000
Switching resources, at least
- B-cycles at rated current 0 50,000 (150,000 *) 30000 30000
- Trips at rated current off 100
Proper on time, ms, not more than 55
Opening time, ms, not more than 15
The total trip time, ms, not more than 25
Reclosure cycle 0-0,3s-IN-IN-15c-180c-IN
Nominal resistance of the main contacts, mO, no more than 60; 40 30 30
Maximum ambient temperature, ° C 55
Minimum ambient temperature, ° C -40
Insulation class according to IEC 932 2
Group resistance to mechanical external factors on GOST17516.1 M6 M7 M7
Maximum height above sea level, m 1000
Weight, kg
- BB / TEL 10 (center distance 200 mm) 35 51 51
- BB / TEL 10 (center distance 250 mm) 37 53 53
The type of control unit BU / TEL-220-05A
BUTEL 100 / 220-12-XX
BUTEL-24 / 60-12-XX
BU / TEL-100 / 220-21-00 BUTEL 100 / 220-12-XX
BUTEL-24 / 60-12-XX
BU / TEL-100 / 220-21-00
Advantages over analogues:
High reliability;
No need for maintenance throughout the service life;
Can be installed in any switchgear cabinets medium voltage;
A wide range of operating supply voltages;
Low power consumption of the auxiliary power supply network;
Functions of remote signaling;
Certification of products for compliance with national standards of consumer countries and international standards;
A wide range of services and customer support throughout the entire life cycle of products;
Environmental cleanliness and safety for the environment.
The development stage readiness:
Tested experimental exploitation order
Description of the development:
() During the reconstruction of the old switch is mounted and the drive instead set switching module BB / TEL-10. The design of the switching module is the reconfigurable framework supporting structure for ease and convenience during installation works in one cell without disconnecting the neighboring. Such a process of modernization of KSO (CSGN) is the most economical and least time-consuming.
Certif
1
corresponds technical description
Conforms to technical characteristic
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|