Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

SWITCH MODULES CM / TEL WITH A VACUUM BREAKER BB / TEL-10 FOR MODERNIZATION KRU IN RENEWABLE ENERGY PRODUCTION OR FACTORY SWITCHING MODULES KM / TEL VACUUM CIRC


Purpose of the development: Коммутационные модули с вакуумными выключателями BB/TEL-10 предназначены для реконструкции выкатных элементов комплектных распределительных устройств (КРУ) с выключателями ВМП-10П, ВМПП-10, ВМП-10К, ВМП-10Е, ВМПЕ-10, ВМГ-133-10 в основном на объектах заказчика. Для КРУ (КРУН) с выкатными элементами наружной и внутренней установки: К-IIIу К-IV К-VIу К-IX КР-10У4 К-XII К-XIII К-XXVI К-34 К-37 КРУ2-10 КРУ2-10Б КРУ2-10Э/Э КР-10-500 К2-03 К3-02 CSIM HL4-7 RSW VD-4 ST7(9) КВС-09 КВВО-2 КОФ-120 КРУ-II-Э КЭ-6(10) КРУПЭ-6(10) КРУЭ-6(10)В КРУЭПЭ-6П

Technical characteristic: Basic specifications Parameter Rated breaking current (kA) / rated current (A) 12.5 / 630; 20/630; 20/1000 20/1600 25/2000 ** 31.5 / 2000 ** Rated voltage 10 kV Rated current, A 630; 1000 1600 2000 Rated breaking current kA 12.5; 20 20 25; 31.5 The current withstand, kA (peak value) 32; 51 51 63; 80 Withstanding thermal current, 3 sec., KA 12,5; 20 20 25; 31.5 Rated breaking current of single capacitor bank 800 A Power frequency test voltage, 42 kb Mechanical operations, operations-0, at least 50,000 (150,000 *) 30000 30000 Switching resources, at least - B-cycles at rated current 0 50,000 (150,000 *) 30000 30000 - Trips at rated current off 100 Proper on time, ms, not more than 55 Opening time, ms, not more than 15 The total trip time, ms, not more than 25 Reclosure cycle 0-0,3s-IN-IN-15c-180c-IN Nominal resistance of the main contacts, mO, no more than 60; 40 30 30 Maximum ambient temperature, ° C 55 Minimum ambient temperature, ° C -40 Insulation class according to IEC 932 2 Group resistance to mechanical external factors on GOST17516.1 M6 M7 M7 Maximum height above sea level, m 1000 Weight, kg - BB / TEL 10 (center distance 200 mm) 35 51 51 - BB / TEL 10 (center distance 250 mm) 37 53 53 The type of control unit BU / TEL-220-05A BUTEL 100 / 220-12-XX BUTEL-24 / 60-12-XX BU / TEL-100 / 220-21-00 BUTEL 100 / 220-12-XX BUTEL-24 / 60-12-XX BU / TEL-100 / 220-21-00

Advantages over analogues: High reliability; No need for maintenance throughout the service life; Can be installed in any switchgear cabinets medium voltage; A wide range of operating supply voltages; Low power consumption of the auxiliary power supply network; Functions of remote signaling; Certification of products for compliance with national standards of consumer countries and international standards; A wide range of services and customer support throughout the entire life cycle of products; Environmental cleanliness and safety for the environment.

The development stage readiness: Tested experimental exploitation order

Description of the development:
()
During the reconstruction of the old switch is mounted and the drive instead of his carriage-type element is installed switching module BB / TEL-10. The design of the switching module is the unified support structure for ease and convenience when carrying out installation work in one cell without disconnecting the neighboring.

Certif 1

corresponds technical description
Conforms to technical characteristic

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: