CONTROL AND SIGNALIZATION BLOCK (CSB-2U)


Purpose of the development: PURPOSED FOR AUTOMATIC CONTROL AND SIGNALIZATION OF TECHNOLOGIAL PROCESS ON UNIFORM CURRENT SIGNAL 4-20 MILLIAMPERES OF CORRESPONDING PHYSICAL MAGNITUDES SENSORS (PRESSURE, LEVEL, TEMPERATURE, SHIFT, ETC. )

Recommended application field: РАЗЛИЧНЫЕ ОБЛАСТИ ПРОМЫШЛЕННОСТИ, ГДЕ ТРЕБУЕТСЯ АВТОМАТИЧЕСКОЕ УПРАВЛЕНИЕ ТЕХНОЛОГИЧЕСКИМИ ПРОЦЕССАМИ.

Technical characteristic: SUPPLY VOLTAGE - 220 VOLTS, 50 HERTZ; POWER CONSUPTION -NO MORE THEN 10 WATTS; POWER HANDLING - NO MORE THEN 500 WATTS; INSTALLATION ACCURACY OF OPERATION OF OUTPUT RELAY STHRESHOLD - 0.5 % FROM THE LEVE L OF OUTPUT SIGNAL; INPUT SIGNAL - 4-20 MILLIAMPERES ;INPUT RESISTANCE - 100 OHMS ;DISCHRGE QUANTITY OF NUMERICAL NOTATION - 4; MASS - 2.5 KILOGRAMMESWARRANTY ASSURANCE - 18 MOTHS; MEAN LIFETIME - 12 YEARS ; AIR TEMPERATURE - 0-50 C UNDER REALIVE HUMIDITY UP TO 98% UNDER TEMPERATURE OF 35 C

Advantages over analogues: CSB-4U ALLOWS TO CREATE 4 SIGNAL MONITORING LEVELS AND CONTROL THE TECHNOLOGICAL PROCESS BY MEANS OF RELAY WITH INDICATION OF THEIR CONDITION.

The development stage readiness: Introduced in production

Description of the development:
()
FOR JUNCTION WITH THE RESOURCE OF UNIFORM SIGNAL THERE IS A CONNECTION INSTALLED ON THE FRAME AND FOR CONNECTION OF POWER CIRCUIT THERE ARE FOUR HERMETICALLY OUTPUTS. ON THE FRONT COVER OF THE BLOCK THERE ARE: DIGITAL READOUT OPENINGS AND FOUR CEILING INDICATORS. LUMINISCENCE OF CEILING INDICATOR SHOWS THE OBTAINING OF SETTING VALUATION PARAMETER. DIGITAL READOUT ALLOWS IN PERCENTAGE TO DISPLAY INPUT SIGNAL WITHIN THE LIMITS FROM 0 TO 100% ALSO THERE IS POSSIBLITY FOR ITS SETTING ON ALL KINDS OF READINGS WITHIN THE LIMITS FROM 0 TO 1999C ALONG WITH PUTTING OF A POINT IN THE NECESSARY PLACE.

corresponds technical description
Conforms to technical characteristic

Possibility of transfer abroad:
Licence's sale
Realization of finished commodity

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: