TRENAR-02 - APPARATUS FOR ELECTROSTIMULATION WITH BIOLOGICAL FEEDBACK


Purpose of the development: For mass use in clinics, rehabilitation centers, sanatoriums, sports facilities, at home, on the recommendation and under the supervision of a doctor.

Recommended application field: In medicine with neurology (severe diseases of the neuromuscular system).

Technical characteristic: - stimulation signal - rectangular pulses: frequency - 40-200 Hz, duty cycle - 5; - maximum intensity of stimulation current: - 50 mA; - the registration range of the electromyogram is 10-300 V; - the range of recording the pulse rate is 40-200 beats per minute; - the frequency range of the EMG frequency is 20-200 Hz; - external power supply (adapter with 220 V power supply) with an output voltage of 12 V; - overall dimensions - 225x160x78.5 mm; - weight - 1,5 kg.

Advantages over analogues: In comparison with foreign analogues has a wider range of functions and a significantly lower cost (6-7 times).

The development stage readiness: Ready for application

Description of the development:
()
Training programs. Training of forced muscle contractions in the programs of electrical stimulation, which are "read" from the patient's own healthy muscles or the muscles of another person (instructor) with their arbitrary reduction and are transmitted to the muscles that train, in the online mode - a new function in devices of this purpose. Training the ratio of arbitrarily-forced contractions of muscles. Forced cuts are triggered by arbitrary contractions of the same muscle when the threshold is overcome in the online mode. Training of arbitrary muscle contractions under the visual and auditory control of the performance of the training task with the help of biofeedback. A variety of programs allows you to personalize your training at every stage of rehabilitation. Additional programs allow you to monitor the heart rate and the average frequency of EMG muscle that is trained. He passed positive clinical trials in the Alexander Clinical Hospital, Kiev and approbation in the Kiev City Clinical Hospital № 3. It is entered in the State register of medical equipment and medical products of Ukraine. It is allowed for use in clinical practice.

corresponds technical description
Ready for implementation

Possibility of transfer abroad:
Combinated reduction to industrial level
Creation of joint enterprise
Realization of finished commodity
Joint production, sale, exploitation

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: