SECONDARY MILITARY STANDARD OF UNIT OF ELECTRIC VOLTAGE OF AC FROM 0.1 V TO 1000 V IN THE RANGE OF FREQUENCIES FROM 10 Hz TO 30 MHz (VOU 08-07-01-09)


Purpose of the development: The input 08-07-01-09 is intended for reproduction, storage of a unit of voltage from 0,1 V to 1000 V AC and transmission of its size to military model measuring instruments 1-2 discharges (type PNTZ-6, PNTZ-12 etc.) In the dynamic (0.001 - 10 * 1000) B and frequency 20 Hz - Z0 MHz ranges.

Recommended application field: Attestation of exemplary measuring instruments of alternating current voltage 1 and 2 discharges (type PNTZ-6, PNTZ-12, etc.) as on 08-07-01-09, as well as in the conditions of metrological parts. Certification of sample instruments for measuring the voltages of alternating current 1 and 2 bits (type PNTZ-6, PNTZ-12, etc.) as on the 08-08-07-09 VVETU, as well as in the conditions of metrological parts.

Technical characteristic: - the range of values of electric AC voltage: 0.001 V - 1000 V; - frequency range: 10 Hz - 30 MHz; - non-exclusive systematic error of reproduction of the unit of variable voltage under normal operating conditions: 0,00001 - 3 * 0,001; - random error of reproduction of the unit of variable voltage in the form of the mean square deviation: 5 * 0,00001 - 1 * 0,001; - error of transfer of the unit size of the variable voltage, which is characterized by the mean square deviation of the result of measurements: 5 * 0,00001 - 5 * 0,001; - instability of the standard in the normal conditions of operation for 1 year, not more: 0,00001 - 3 * 0,001; - power supply, no more: 2 kVA; - the time of setting the operating mode, not more than: 2 hours; - electric power of insulation of measurement circles, not less: 2kV; - impedance of insulation of measuring circles, not less: 500 M; - time of continuous work (without taking into account heating with a subsequent break of at least 2 hours), no more: 8 hours. - the range of values of AC voltage: 0.001 V - 1000 V; - frequency range: 10 Hz - 30 MHz; - non-exclusive systematic error of reproduction of an AC unit under normal operating conditions: 0.00001-3 * 0.001; - random error of reproduction of the unit of AC in the form of the root mean square deviation: 5 * 0.00001 - 1 * 0.001; - the error of transmitting the size of the unit of AC, which characterizes the mean square deviation of the measurement result: 5 * 0.00001 - 5 * 0.001; - instability of the standard under normal operating conditions for 1 year, not more than: 0,00001 - 3 * 0,001; - power supply, not more than: 2kVA; - time of establishment of the operating mode, not more than: 2 hours; - electric power of isolation of measurement circuits, not less: 2 kV; - impedance of isolation power of measuring circuits, at least: 500 M; - time of continuous operation (without warming up, followed by a break of at least 2 hours), not more than: 8 hours.

The development stage readiness: Introduced in production

corresponds technical description
Conforms to technical characteristic

Possibility of transfer abroad:
Licence's sale

Photo

Country Ukraine

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: