MEASURING COMPLEX "PEER BETA-GAMMA-SHR"
Purpose of the development:
For measuring ionizing radiation.
Recommended application field:
Medicine. Control of internal exposure and staff, practical radiation medicine.
Technical characteristic:
Specifications of measuring equipment allow you to use it as the primary measuring complex and as expert installation.
Gamma - channel :
o energy range of detected gamma radiation - 0.05 - 3.0 ;
o type of detector detection units stsingillyatsionny NaI (Tl) - (150x100 mm and 63x63 mm);
o range of measured activity in the human body from 7.5-10 to 8.5-10 in 5Bk ;
o the minimum detectable activity of 137Cs in the adult human body - 300 Bq;
o radionuclides controlled in standard mode, Sr- 90 , Cs- 137 , I- 131 , Co -60 , K -40 , etc.
o energy resolution at 0.662 MeV , % :
y a feed channel 10 in no more than 30 ;
o basic error of measurement,% :
y ± 30 % channel to channel , ± 50 %
Beta Channel :
o type and range of detected radiation from 0.2 to 3.5 MeV ;
o type of detector combined ( phoswich ) detectors based on activated paraterphenyl 63x4 mm crystals and CsI (Na) (NaI (Tl)) 63x40 mm;
o the minimum detectable activity of 90Sr in the adult human body during the measurement time 30 min. Bq 1.1 kBq / kg;
o erratic readings during continuous operation ( 12hours ),% ± 2% and ± 5% respectively.
Advantages over analogues:
There is no analogs developed complex in Belarus.
The development stage readiness:
tested in laboratory condition
Technical and economic effect:
Implementation of measuring complex to prevent undue exposure of the population has a social effect.
Description of the development:
() Specifications of measuring equipment allow you to use it as the primary measuring complex and as expert installation.
Gamma - channel :
o energy range of detected gamma radiation - 0.05 - 3.0 ;
o type of detector detection units stsingillyatsionny NaI (Tl) - (150x100 mm and 63x63 mm);
o range of measured activity in the human body from 7.5-10 to 8.5-10 in 5Bk ;
o the minimum detectable activity of 137Cs in the adult human body - 300 Bq;
o radionuclides controlled in standard mode, Sr- 90 , Cs- 137 , I- 131 , Co -60 , K -40 , etc.
o energy resolution at 0.662 MeV , % :
y a feed channel 10 in no more than 30 ;
o basic error of measurement,% :
y ± 30 % channel to channel , ± 50 %
Beta Channel :
o type and range of detected radiation from 0.2 to 3.5 MeV ;
o type of detector combined ( phoswich ) detectors based on activated paraterphenyl 63x4 mm crystals and CsI (Na) (NaI (Tl)) 63x40 mm;
o the minimum detectable activity of 90Sr in the adult human body during the measurement time 30 min. Bq 1.1 kBq / kg;
o erratic readings during continuous operation ( 12hours ),% ± 2% and ± 5% respectively.
Analogs developed complex in Belarus no . Developed a measurement system corresponds to the best world standards ( superior Anti-Cancer Committee Australia) .
Measurement process is environmentally friendly. Completed fabrication of prototype model of measuring complex research conducted tests .
Possibility of transfer abroad:
Licence's sale Technological document's sale
Photo
Country
Belarus
For additional information turn to: E-mail: gal@uintei.kiev.ua
|