Declared technologies base

TRANSFER OF INNOVATIONAL TECHNOLOGIES

MEASURING COMPLEX "PEER BETA-GAMMA-SHR"


Purpose of the development: For measuring ionizing radiation.

Recommended application field: Medicine. Control of internal exposure and staff, practical radiation medicine.

Technical characteristic: Specifications of measuring equipment allow you to use it as the primary measuring complex and as expert installation. Gamma - channel : o energy range of detected gamma radiation - 0.05 - 3.0 ; o type of detector detection units stsingillyatsionny NaI (Tl) - (150x100 mm and 63x63 mm); o range of measured activity in the human body from 7.5-10 to 8.5-10 in 5Bk ; o the minimum detectable activity of 137Cs in the adult human body - 300 Bq; o radionuclides controlled in standard mode, Sr- 90 , Cs- 137 , I- 131 , Co -60 , K -40 , etc. o energy resolution at 0.662 MeV , % : y a feed channel 10 in no more than 30 ; o basic error of measurement,% : y ± 30 % channel to channel , ± 50 % Beta Channel : o type and range of detected radiation from 0.2 to 3.5 MeV ; o type of detector combined ( phoswich ) detectors based on activated paraterphenyl 63x4 mm crystals and CsI (Na) (NaI (Tl)) 63x40 mm; o the minimum detectable activity of 90Sr in the adult human body during the measurement time 30 min. Bq 1.1 kBq / kg; o erratic readings during continuous operation ( 12hours ),% ± 2% and ± 5% respectively.

Advantages over analogues: There is no analogs developed complex in Belarus.

The development stage readiness: tested in laboratory condition

Technical and economic effect: Implementation of measuring complex to prevent undue exposure of the population has a social effect.

Description of the development:
()
Specifications of measuring equipment allow you to use it as the primary measuring complex and as expert installation. Gamma - channel : o energy range of detected gamma radiation - 0.05 - 3.0 ; o type of detector detection units stsingillyatsionny NaI (Tl) - (150x100 mm and 63x63 mm); o range of measured activity in the human body from 7.5-10 to 8.5-10 in 5Bk ; o the minimum detectable activity of 137Cs in the adult human body - 300 Bq; o radionuclides controlled in standard mode, Sr- 90 , Cs- 137 , I- 131 , Co -60 , K -40 , etc. o energy resolution at 0.662 MeV , % : y a feed channel 10 in no more than 30 ; o basic error of measurement,% : y ± 30 % channel to channel , ± 50 % Beta Channel : o type and range of detected radiation from 0.2 to 3.5 MeV ; o type of detector combined ( phoswich ) detectors based on activated paraterphenyl 63x4 mm crystals and CsI (Na) (NaI (Tl)) 63x40 mm; o the minimum detectable activity of 90Sr in the adult human body during the measurement time 30 min. Bq 1.1 kBq / kg; o erratic readings during continuous operation ( 12hours ),% ± 2% and ± 5% respectively. Analogs developed complex in Belarus no . Developed a measurement system corresponds to the best world standards ( superior Anti-Cancer Committee Australia) . Measurement process is environmentally friendly. Completed fabrication of prototype model of measuring complex research conducted tests .

Possibility of transfer abroad:
Licence's sale
Technological document's sale

Photo

Country Belarus

For additional information turn to:
E-mail: gal@uintei.kiev.ua

or fill out the form:
Organization name :
Address :
Settlement account :
Bank :
MFO :
OKPO code :

Scientific organization tutor's data :
Surname :
Name :
Patronymic :
Scientific degree :
Phone :
Fax :
E-mail :
Cooperation proposals (joint patent, joint enterprise, assembly sale and so on :
country: