ECONOMIC SMALL GAMMA-RAY DETECTORS
Purpose of the development:
Continuous monitoring of gamma-ray photons.
Recommended application field:
Operating in extreme conditions (under water in tanks filled with opaque oil on board spacecraft).
Technical characteristic:
Energy range 40 keV - 1 MeV; power supply requirements: voltage 15 - 8 V, load current - 1 mA; battery duration of continuous operation from a single battery "Krona" 600 hours; finding with certainty 60% for 1s excess photon flux above the level of 137Cs, which creates a dose of 0.5 mSv / h (50 mR / h).
Advantages over analogues:
Increasing efficiency measurements under conditions that require a decision (at the customs office, scrap metal items, ground work in the contaminated area).
The development stage readiness:
Introduced in production
Description of the development:
() Detector Na (Ta) (d = 25 mm, h = 45 mm), a photomultiplier, stabilized power supply, processing unit, the battery "Krona".
Cylinder 45 mm diameter, 150 mm in height, weighing 0.5 kg.
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|