HEAT EXCHANGER PDP-1, 5
Purpose of the development:
Thermal insulator is designed for use in stationary gas consumption for heating and industrial boilers for the purpose of heating and humidifying the air blow through the use of waste gases, heat boilers.
Recommended application field:
Scope of application - boiler houses with boilers with heat-0.67 MW (steam 1 t / h).
Technical characteristic:
Specifications:
- Heating capacity of 0.1 MW ;
- The cost of raw gas , cubic meters . / Hr 1500 ;
- Coefficient of excess air in the gases 1.35 ;
- Gas temperature , ° C:
at input 200;
at the output 75;
- The cost of air , cubic meters . / Hr 1360 ;
- Air temperature ° C :
inlet 10;
at the output 60 ;
- The cost of the water circulating t / h 3 ;
- ° C Water temperature :
at the outlet of the heater 60 ;
vododogrevatelya outlet 90;
- The aerodynamic resistance, Pa :
gas side 300 ;
300 air-side ;
- Hydraulic resistance, 12 kPa ;
- The amount of gas saved , cubic m . / Hr 10;
- Specific electricity consumption ,
kWh . / GJ 3 ;
- Overall dimensions 1616x940x2840 ;
- Weight 992 kg .
Advantages over analogues:
Heat Exchanger PDP- 1, 5 has such advantages as compared with domestic and foreign counterparts - heat recovery , which include air heater pin :
- Lower height due to the use of the surface of the heater and air heater perekresno current contact ;
- Heating the water circulating through the use vododogrevatelya surface to a higher temperature , which provides a greater degree of humidification of air blow and the corresponding reduction of emissions of nitrogen oxides ;
- An increase in the moisture content of the blast air thanks to the heater ;
- Less drag with the gas and the air side ;
- Improving the reliability of the gas and air paths boiler installation thanks to the gas heater and air superheater ;
- Eliminating the need for external heat consumer ( autonomy );
- No use of heat from an external source .
The development stage readiness:
Introduced in production
Technical and economic effect:
Increase the fuel utilization factor of 10-12%. Reducing emissions of nitrogen oxides is 50 - 60%. Payback period of capital cost of installing a heat exchanger, excluding environmental effect is to - 3 years.
Information about newness of the development:
there are Ukrainian patents -- 1 items
Possibility of transfer abroad:
Licence's sale Realization of finished commodity
Photo
Country
Ukraine
For additional information turn to: E-mail: gal@uintei.kiev.ua
|